Codemath.com


Residential Single Phase Service - Canada
100A, Eye Bolt, Copper Conductors, #6 Bare Neutral (if allowed)

CAUTION
A bare neutral is not allowed in all circumstances.
Reduced neutral size is only allowed in some circumstances.

Material Check List
Heading Qty Description Part Number
       
Service  
 
  1" Service Head  
  Eye Bolt with Nut  
  2" x 2" Washer (eye bolt in building)  
  Blank Cover (cover eye bolt hole into building)  
  4" x 4" Washer (eye bolt in attic)  
  2 x 4 lumber (backing for eye bolt in attic)  
  #6 X 1¼" Wood Screws (attach blank cover to wall)  
Meter  
 
  1" Meter Socket Hub  
  100 Amp Overhead Meter Socket  
  Back Board (behind meter socket)  
  1" screws (attach back-board to wall)  
  2" Screws (attach meter to wall through back-board)  
  Washers (for screws)  
Conduit  
 
  1" EMT Conduit  
  1" EMT Water Tight Connectors  
  1" EMT Set Screw Connector  
  1" EMT Water Tight Couplings  
  1" EMT Straps  
  Screws (attach straps)  
  1" LB (entry into building)  
  1" Nylon Bushing (inside meter socket)  
  Silicone Sealant (seal penetration into building)  
  Dux Seal (seal inside LB)  
  1" Rigid Coupling (extend conduit inside building)  
  1" Nipple (extend conduit inside building)  
  1" Locknuts (for nipple)  
Panel  
 
  Panel with 100 Amp Main Breaker  
  Plywood backing for Panel  
  Vapor barrier (behind plywood for panel)  
  1½" Screws (attach plywood to wall)  
  Concrete Anchors (attach plywood to wall)  
  ¾ " Screws (secure panel to plywood)  
  Sealing Tape for vapor barrier  
Service Wiring  
 
  #6 Bare Copper  
  #3 Copper RW90 Black  
  Sealing Material (seal inside conduit entering building)  
  Wire Lube  
Grounding  
 
  #6 AWG Bare Copper  
  Ground Clamps for Incoming Water Line (if metal)  
  Ground Plate (if not using water line)  
  2 Ground Rods if not using water line  
  Ground Clamps for Ground Rods  
Bonding  
 
  1" Ground Bushing (connector inside panel)  
  #6 AWG Bare Copper  
  Ground Clamps (gas, water, sewer)  
  Cable Connector (ground/bond wire entering panel)  
  Cable Ties (securing ground to water line)  
Breakers  
 
  2 Pole 40 Amp Narrow Range Breaker  
  2 Pole 30 Amp Narrow Dryer Breaker  
  Air Conditioner Breaker  
  Kitchen Counter Plug 2 Pole Breaker  
  Kitchen Counter Plug 20 amp Breaker  
  15 Amp Breakers (narrow/twin)  
  AFCI breaker (bedroom plugs)  
Panel Wiring  
 
  ½ " NMD connectors  
  ¾ " NMD connector for range cable  
  4" Junction Boxes (extending wires)  
  4" Junction Box covers  
  14/2 NMD (extending wires)  
  14/3 NMD (extending wires)  
  12/2 NMD (extending wires)  
  10/3 NMD (extending dryer wires)  
  8/3 NMD (extending range wires)  
Old Wiring  
 
  GFI Blank Front (ungrounded circuits)  
  Handy Box for GFI  
  Cover for GFI  
  Plastic Connectors (knob & tube entering a box)  
       
       

©2011 Sandraft Sales Corp

Last Modified: December 14, 2011

Codemath.com